#smartctl -a /dev/hda                                                                       [/dev/pts/0 # 1815 - 0 - 0 # 14 day 00:46:04 # 2.22 - 1.06 - 0.41]
smartctl version 5.38 [i686-pc-linux-gnu] Copyright (C) 2002-8 Bruce Allen                                                                                                                    
Home page is http://smartmontools.sourceforge.net/                                                                                                                                            

=== START OF INFORMATION SECTION ===
Device Model:     FUJITSU MHW2040AT 
Serial Number:    K00VT7626PSV      
Firmware Version: 0000000B          
User Capacity:    40.007.761.920 bytes
Device is:        Not in smartctl database [for details use: -P showall]
ATA Version is:   7                                                     
ATA Standard is:  ATA/ATAPI-7 T13 1532D revision 4a                     
Local Time is:    Tue Dec 22 21:58:05 2009 CET                          
SMART support is: Available - device has SMART capability.              
SMART support is: Enabled                                               

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x00) Offline data collection activity
                                        was never started.              
                                        Auto Offline Data Collection: Disabled.
Self-test execution status:      (   0) The previous self-test routine completed
                                        without error or no self-test has ever  
                                        been run.                               
Total time to complete Offline                                                  
data collection:                 ( 276) seconds.                                
Offline data collection                                                         
capabilities:                    (0x7b) SMART execute Offline immediate.        
                                        Auto Offline data collection on/off support.
                                        Suspend Offline collection upon new         
                                        command.                                    
                                        Offline surface scan supported.             
                                        Self-test supported.                        
                                        Conveyance Self-test supported.             
                                        Selective Self-test supported.              
SMART capabilities:            (0x0003) Saves SMART data before entering            
                                        power-saving mode.                          
                                        Supports SMART auto save timer.             
Error logging capability:        (0x01) Error logging supported.                    
                                        No General Purpose Logging support.         
Short self-test routine                                                             
recommended polling time:        (   2) minutes.                                    
Extended self-test routine                                                          
recommended polling time:        (  35) minutes.                                    
Conveyance self-test routine                                                        
recommended polling time:        (   2) minutes.                                    
SCT capabilities:              (0x003d) SCT Status supported.                       
                                        SCT Feature Control supported.              
                                        SCT Data Table supported.                   

SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAG     VALUE WORST THRESH TYPE      UPDATED  WHEN_FAILED RAW_VALUE
  1 Raw_Read_Error_Rate     0x000f   100   100   046    Pre-fail  Always       -       159442
  2 Throughput_Performance  0x0005   100   100   030    Pre-fail  Offline      -       11075584
  3 Spin_Up_Time            0x0003   100   100   025    Pre-fail  Always       -       1
  4 Start_Stop_Count        0x0032   100   100   000    Old_age   Always       -       64
  5 Reallocated_Sector_Ct   0x0033   100   100   024    Pre-fail  Always       -       8589934592000
  7 Seek_Error_Rate         0x000f   100   100   047    Pre-fail  Always       -       294
  8 Seek_Time_Performance   0x0005   100   100   019    Pre-fail  Offline      -       0
  9 Power_On_Hours          0x0032   069   069   000    Old_age   Always       -       15771
 10 Spin_Retry_Count        0x0013   100   100   020    Pre-fail  Always       -       0
 12 Power_Cycle_Count       0x0032   100   100   000    Old_age   Always       -       64
192 Power-Off_Retract_Count 0x0032   100   100   000    Old_age   Always       -       28
193 Load_Cycle_Count        0x0032   083   083   000    Old_age   Always       -       354115
194 Temperature_Celsius     0x0022   100   100   000    Old_age   Always       -       33 (Lifetime Min/Max 16/46)
195 Hardware_ECC_Recovered  0x001a   100   100   000    Old_age   Always       -       2517
196 Reallocated_Event_Count 0x0032   100   100   000    Old_age   Always       -       456916992
197 Current_Pending_Sector  0x0012   100   100   000    Old_age   Always       -       0
198 Offline_Uncorrectable   0x0010   100   100   000    Old_age   Offline      -       0
199 UDMA_CRC_Error_Count    0x003e   200   200   000    Old_age   Always       -       0
200 Multi_Zone_Error_Rate   0x000f   100   100   060    Pre-fail  Always       -       22553
203 Run_Out_Cancel          0x0002   100   100   000    Old_age   Always       -       429542343499

SMART Error Log Version: 1
No Errors Logged

SMART Self-test log structure revision number 1
No self-tests have been logged.  [To run self-tests, use: smartctl -t]


SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.